①. 換(huan)(huan)(huan)熱(re)(re)(re)(re)器(qi)(qi)(qi)的芯(xin)指的就是換(huan)(huan)(huan)熱(re)(re)(re)(re)器(qi)(qi)(qi)管(guan)(guan)(guan)束(shu)(shu),“檢(jian)修抽(chou)芯(xin)”一般就兩種(zhong)換(huan)(huan)(huan)熱(re)(re)(re)(re)器(qi)(qi)(qi)而言,即浮頭式換(huan)(huan)(huan)熱(re)(re)(re)(re)器(qi)(qi)(qi)和U形管(guan)(guan)(guan)式換(huan)(huan)(huan)熱(re)(re)(re)(re)器(qi)(qi)(qi),浮頭式換(huan)(huan)(huan)熱(re)(re)(re)(re)器(qi)(qi)(qi)抽(chou)芯(xin)前要拆(chai)管(guan)(guan)(guan)箱(xiang)、外頭蓋(封頭)、小浮頭后方(fang)可用(yong)抽(chou)芯(xin)機從(cong)管(guan)(guan)(guan)箱(xiang)側將管(guan)(guan)(guan)束(shu)(shu)抽(chou)出來。U形管(guan)(guan)(guan)式換(huan)(huan)(huan)熱(re)(re)(re)(re)器(qi)(qi)(qi)只需將管(guan)(guan)(guan)箱(xiang)拆(chai)除即可進行抽(chou)芯(xin)。
②. 固定管(guan)板換熱器一般不(bu)進(jin)行機械(xie)沖洗和“檢(jian)修抽芯”,僅進(jin)行化(hua)學清洗。管(guan)束管(guan)子腐蝕后(hou)與殼體一同(tong)報廢(fei)。
③. 現(xian)在抽(chou)芯作業,常(chang)使用方便的換熱(re)(re)器抽(chou)芯作業車,見圖7.29(a),在做設備布置設計時,需考慮檢修的空(kong)間。對于小型的換熱(re)(re)器,也(ye)可(ke)采用人工(gong)抽(chou)芯作業。
④. 某裝置的管(guan)殼式換(huan)熱(re)(re)器總重49t,芯(xin)重26t,外形尺(chi)寸(cun)為2mx9.1mm,結焦嚴(yan)重,導致檢修(xiu)抽(chou)芯(xin)困難(nan)。抽(chou)芯(xin)時,采用了電(dian)加(jia)熱(re)(re)器、龍門架、吊車、牽引裝置以(yi)及(ji)機具等,先采用履帶式電(dian)加(jia)熱(re)(re)器對該換(huan)熱(re)(re)器進行電(dian)加(jia)熱(re)(re),使結焦物熔(rong)化,然后進行抽(chou)芯(xin),見圖7.29(b)。
⑤. 與反應器(qi)直接(jie)相(xiang)關的立式換(huan)熱器(qi),可布置在反應器(qi)框架內,并應有機動吊裝機抽(chou)出管(guan)束空間(jian)。
⑥. 當不(bu)能采用機動吊(diao)裝機具抽出管(guan)(guan)束時,可在框架上設(she)計(ji)吊(diao)車梁(liang),為拆卸管(guan)(guan)箱蓋板、管(guan)(guan)箱、管(guan)(guan)束及外(wai)頭蓋(封頭)用(U形管(guan)(guan)式換熱器沒有外(wai)頭蓋)。檢(jian)修吊(diao)車梁(liang)的(de)(de)高度及大小見(jian)圖(tu)7.30(a)。如圖(tu)7.30(b)所示,配(pei)管(guan)(guan)設(she)計(ji)時,需注意(yi)吊(diao)裝空間的(de)(de)配(pei)管(guan)(guan)應設(she)計(ji)成(cheng)可拆卸式的(de)(de)。