1. 排(pai)(pai)放(fang)(fang)至大(da)氣的(de)安全(quan)閥。安裝在塔頂部人孔(kong)下的(de)第一層平(ping)(ping)(ping)臺上(shang)(shang)。排(pai)(pai)放(fang)(fang)管是(shi)從塔頂出(chu)(chu)(chu)(chu)料(liao)管的(de)垂直管段上(shang)(shang)引出(chu)(chu)(chu)(chu)。排(pai)(pai)至大(da)氣中之(zhi)氣體(ti)為無毒(du)(du)氣體(ti)時,排(pai)(pai)管末端高(gao)(gao)度應(ying)在半(ban)徑7.5m以內的(de)最高(gao)(gao)平(ping)(ping)(ping)臺以上(shang)(shang)2.5m。對(dui)(dui)排(pai)(pai)放(fang)(fang)氣為有(you)毒(du)(du)或易燃、易爆、有(you)腐蝕性(xing)的(de)介質(zhi),對(dui)(dui)連續(xu)排(pai)(pai)放(fang)(fang)的(de)氣體(ti)出(chu)(chu)(chu)(chu)口管應(ying)高(gao)(gao)出(chu)(chu)(chu)(chu)水(shui)平(ping)(ping)(ping)半(ban)徑20m范(fan)圍(wei)內的(de)操作(zuo)平(ping)(ping)(ping)臺以上(shang)(shang)3.5m,不(bu)得有(you)平(ping)(ping)(ping)臺。對(dui)(dui)間歇排(pai)(pai)放(fang)(fang)可燃氣體(ti)出(chu)(chu)(chu)(chu)口管應(ying)高(gao)(gao)出(chu)(chu)(chu)(chu)水(shui)平(ping)(ping)(ping)半(ban)徑10m范(fan)圍(wei)內的(de)操作(zuo)平(ping)(ping)(ping)臺或建筑物(wu)頂3.5m,不(bu)得有(you)平(ping)(ping)(ping)臺或建筑物(wu)。排(pai)(pai)出(chu)(chu)(chu)(chu)管低(di)點挖$6mm或φ9mm的(de)淚孔(kong)。
2. 對于易燃易爆介質的(de)(de)管(guan)(guan)(guan)(guan)(guan)(guan)線(xian)上(shang)應配密閉收集的(de)(de)導管(guan)(guan)(guan)(guan)(guan)(guan);出(chu)(chu)口管(guan)(guan)(guan)(guan)(guan)(guan)要有充分的(de)(de)支(zhi)撐。排(pai)放(fang)到火炬(ju)(ju)系統的(de)(de)安(an)全(quan)(quan)閥:排(pai)放(fang)管(guan)(guan)(guan)(guan)(guan)(guan)從塔頂出(chu)(chu)料管(guan)(guan)(guan)(guan)(guan)(guan)的(de)(de)垂直管(guan)(guan)(guan)(guan)(guan)(guan)段(duan)上(shang)引出(chu)(chu);安(an)全(quan)(quan)閥安(an)裝在(zai)高于火炬(ju)(ju)總管(guan)(guan)(guan)(guan)(guan)(guan)的(de)(de)塔平(ping)臺上(shang)。在(zai)塔頂氣相管(guan)(guan)(guan)(guan)(guan)(guan)線(xian)上(shang)之泄(xie)放(fang)閥,其(qi)設置(zhi)(zhi)位置(zhi)(zhi)最好在(zai)這(zhe)支(zhi)氣相管(guan)(guan)(guan)(guan)(guan)(guan)線(xian)所(suo)經(jing)過的(de)(de)操(cao)作平(ping)臺中最低層的(de)(de)操(cao)作平(ping)臺邊(bian),以方便操(cao)作的(de)(de)地方為主,同時管(guan)(guan)(guan)(guan)(guan)(guan)線(xian)盡(jin)量縮短,以減小(xiao)管(guan)(guan)(guan)(guan)(guan)(guan)內(nei)的(de)(de)壓(ya)力(li)降(jiang)及(ji)降(jiang)低成本。配管(guan)(guan)(guan)(guan)(guan)(guan)時要注意從塔頂出(chu)(chu)口到安(an)全(quan)(quan)閥入口間(jian)管(guan)(guan)(guan)(guan)(guan)(guan)段(duan)阻(zu)力(li)降(jiang)要小(xiao)于安(an)全(quan)(quan)閥定壓(ya)值(zhi)(zhi)的(de)(de)3%;安(an)全(quan)(quan)閥出(chu)(chu)口到火炬(ju)(ju)總管(guan)(guan)(guan)(guan)(guan)(guan)之間(jian)的(de)(de)管(guan)(guan)(guan)(guan)(guan)(guan)段(duan)其(qi)阻(zu)力(li)降(jiang)不(bu)大于安(an)全(quan)(quan)閥定壓(ya)值(zhi)(zhi)的(de)(de)10%(工藝專(zhuan)業負(fu)責)。
3. 安全(quan)閥(fa)出口配管坡(po)向(xiang)火炬總管,并(bing)以45°順流從頂部連接,見圖(tu)4.53。
4. 若安(an)全閥(fa)進(jin)出口管上(shang)設有(you)切斷(duan)閥(fa)時,應(ying)當用單閘板閘閥(fa),且閥(fa)桿(gan)應(ying)水平安(an)裝。